Liquid Cooling & Thermal Management

Cold plates, manifolds and heat sinks — wherever power electronics run hot.

MES machines, casts and extrudes the metal components inside liquid cooling and thermal systems — in eight countries, with our own engineers on the floor.

The 5 Forces Reshaping Thermal Design

01

Rack Density

Accelerator draw outpaced air cooling. Direct-to-chip and immersion are mainstream, not experimental.

02

Copper Economics

Since April 2026, Section 232 duty on covered copper is assessed on full customs value, not metal content.

03

Geometry Churn

Every accelerator generation changes the die footprint. Tooling follows on a 12-to-18-month cycle.

04

Leak Risk

Coolant onto energized hardware is not a warranty claim. Pressure integrity is a qualification gate.

05

Deployment Speed

Schedules run in months. Components qualify against a ramp date, not a fiscal calendar.

Why MES

Why Cooling Manufacturers Work With MES

Because thermal parts fail in ways that pass inspection. A cold plate holding 0.025 mm at first article and 0.06 by part four hundred ships clean and throttles the accelerator anyway.

C11000 cold plates with 0.3 mm skived fins. 6061-T6 and 316 manifolds. 6063-T6 heat sinks. A380 cast hardware. The alloys are the easy part — holding the tolerance across four hundred parts is not.

We measure every lot at source. We review the drawing before the tool is cut.

Certified & Global

ISO 9001:2015 since 2009
IATF 16949
NMSDC Minority-Certified
United States, India, China, Mexico, Vietnam & more

We measure at source, every lot

Verified in the supplier’s plant, not on your dock. Flatness, fin geometry and channel cleanliness, on the parts that ship.

We review the drawing first

A bore that cannot hold as-cast. A fin pitch that will not skive at that height. You hear it while it is still a drawing, at no cost.

We pull the heat number at the mill

Not reconstructed on receipt. “Meets the standard” and “came from this heat” are different documents.

We employ the engineers in the plant

Same country, same floor, the day your parts run. Not a quarterly audit the factory prepared for.

0.025 mm
Flatness across the die footprint
388 W/m·K
Copper conductivity — roughly twice aluminum
3,000+
Audited global suppliers
Applications

Six Applications. One Thermal Capability.

Wherever power electronics run hot in a confined space, the same machined plates, manifolds and extruded heat sinks apply. Data centers are the largest case. Not the only one — and MES supplies the components across all six.

01

Data Centers & AI Infrastructure

Accelerator density made air cooling impossible. Direct-to-chip is now standard.

Cold plate

CDU manifold

Pump housing

Cold plates · CDU manifolds · rack manifolds · quick disconnects · immersion tanks · rear-door frames · pump housings

Materials: C11000 copper · 6061-T6 · 6005A-T6 · 316 stainless · CF8M · brass · nickel plating

The spec that matters:
Flatness across the die footprint, verified across the lot.
02

Battery Energy Storage

Air-cooled cabinets are giving way to liquid. Temperature uniformity sets cell life.

Cooling plate

Coolant header

Fan shroud

Cooling plates · coolant manifolds · headers · quick disconnects · duct framing · fan shrouds

Materials: A380 aluminum · 6061-T6 · 6063-T6 · 316 stainless · brass

The spec that matters:
Flatness against the module face. Uneven contact means uneven degradation.
03

Power Conversion & Inverters

A megawatt PCS rejects real heat in a small enclosure.

IGBT heat sink base

Inverter plate

Capacitor bracket

IGBT heat sink bases · liquid-cooled inverter plates · enclosure framing · fan shrouds · capacitor brackets

Materials: 6063-T6 · 6061-T6 · A380 aluminum · C11000 copper

The spec that matters:
Flatness and surface finish under the module. TIM fills roughness, not gaps.
04

UPS & Critical Power

Each modular bay is a dense stack of power electronics.

Module chassis

Internal hardware

Gland plate

IGBT heat sink bases · air baffles · shrouds · fan trays · module chassis rails · gland plates

Materials: 6063-T6 · 6005A-T6 · A380 aluminum · Zamak 3/5 zinc

The spec that matters:
Repeatability across a hot-swap interface, dozens of cycles deep.
05

Transformers & Switchgear

Oil rejects heat by convection through up to twenty radiator sections per unit.

Heat exchanger frame

Header

Fan housing

Radiator fin panels · headers · manifolds · fan shrouds · heat exchanger frames · louvers

Materials: 6063-T5 · 6005A-T6 · A380 aluminum · Zamak zinc

The spec that matters:
Straightness tighter than the standard. AA tolerance allows 1.3 mm/m — that is 4 mm on a three-meter panel.
06

EV Charging

A 350 kW cabinet dissipates real heat where the public can touch it.

Module heat sink

Connector cold plate

Cabinet framing

Power module heat sinks · cable and connector cold plates · cabinet framing · fan shrouds · pedestal bases

Materials: 6063-T6 · 6061-T6 · C11000 copper · A380 aluminum · anodized finishes

The spec that matters:
Thermal performance and cosmetic finish specified as one requirement, not two.
Components We Engineer & Deliver

Components We Engineer & Deliver

Four categories. Precision CNC machining, aluminum extrusion, high-pressure die casting and investment casting.

A machined block on the processor, coolant through internal channels. One to eight per server.

Unforgiving in three ways — flatness on the die face, fin geometry, and the sealed joint. All three are machining outcomes, not design outcomes.

Skived Fin Cold Plate — C11000 Copper, CNC Machined

Cold Plate Assembly with Quick-Disconnect Ports

Fin Detail — 0.3 mm Thickness at 0.4 mm Pitch

Machined Aluminum Cold Plate — 6061-T6

Brazed Cover Joint — Pressure Tested

Nickel-Plated Copper Plate for Mixed-Metal Loops

Technical Claims

What Engineers Ask Us About Thermal Component Manufacturing

Five things decide whether a thermal component performs in the field. None is visible on a receiving dock. All five apply equally to a cold plate, a battery cooling plate and an IGBT heat sink base.

Call it out across the contact footprint, not as a general profile tolerance.

A part can be within profile tolerance and still leave a gap over the die. Specify flatness across the contact footprint as its own requirement, state where it is measured, and state whether it is verified on the first article or across the lot. Those three decisions determine whether the part performs — and all three are usually missing from the drawing.

Manufacturing Capabilities

Five Processes. One Partner.

ISO 9001:2015 Certified
IATF 16949 Quality Systems
NMSDC Minority-Owned
Columbus, OH + Monterrey, MX
20–55% Cost Savings
01

CNC Machining

Cold plate bodies, manifolds, headers, sealing faces, heat sink bases. Multi-axis in copper, aluminum and stainless with CMM verification at source.

Tight tolerance · Multi-axis · Copper & aluminum
02

Aluminum Extrusion

Heat sink profiles, framing, coolant headers, rack rails. High aspect ratio fin arrays with precision straightening.

Custom profiles · High aspect ratio · Thermal
03

High-Pressure Die Casting

Fan housings, pump brackets, shrouds, battery cooling plates. 50 to 4,400 tons in aluminum and zinc.

Aluminum · Zinc · High-volume
04

Investment Casting

Pump volutes, valve bodies, complex internal geometry near-net. 10 g to 50 kg, ±0.13 mm on the first 25 mm.

Complex geometry · Near-net-shape · Stainless
05

Forging

High-strength mounting and load-bearing hardware, certified per heat lot.

High-strength · Fatigue resistant · Critical parts
Knowledge Base

LIQUID COOLING MANUFACTURING FAQS

Let's Build the Thermal Layer Behind AI.

Scaling cold plate production, moving a battery thermal design from air to liquid, or defining a supply chain for a platform that does not exist yet — MES delivers the components and the supply chain to get there faster.